GI-46B
TRIODE
The GI-46B triode generates and amplifies RF oscillations in continuous-wave and pulsed operation with anode modulation.
GENERAL
Cathode: indirectly heated,
oxide-coated.
Envelope: metal-caramic with ring leads of cathode, heater and
grid.
Cooling: forced air.
Height: at most 113 mm with heat sink, 69 mm
with no heat sink.
Diameter: at most 65 mm with heat sink, 55 mm with no heat
sink.
Mass: at most 620 g with heat sink, 205 g with no heat sink.
OPERATING ENVIRONMENTAL CONDITIONS | |
Vibration loads: | |
frequencies, Hz | 5-1,000 |
acceleration, m/s² | 98 |
Multiple impacts: | |
acceleration, m/s² | 1,470 |
number of impacts | 4,000 |
Ambient temperature, °C | -60 to +100 |
Relative humidity at +40 °C, % | 95-98 |
BASIC DATA Electrical Parameters | |
Heater voltage (AC or DC), V | 12.6 |
Heater current, A | 2.3-2.6 |
Anode voltage (DC), kV | 2 |
Mutual conductance (at anode current 80 mA), mA/V | 17-26 |
Inverse grid current (at anode current 80 mA), µA | 40 |
Cathode emission current (at anode pulse voltage 400 V, pulse duration 2-5 µs, frequency 50 Hz, grid pulse voltage 400 V), A, at least | 24 |
Penetration factor (at anode current 80 mA, anode voltage change 200 V), % | 0.4-0.8 |
Output power in CW generation mode (at heater voltage 8.5 V, anode voltage 1.5 kV, anode current 350 mA, wavelength 29 cm), W, at least | 120 |
Warm up time, s, at most | 100 |
Interelectrode capacitance, pF: | |
input | 14.5-18.5 |
transfer | 5.1-6.4 |
Limit Operating Values | |
Heater voltage (AC or DC), V: | |
maximum | 13.9 |
minimum | 7.7 |
Anode voltage (DC), kV | 1.9 |
Peak anode voltage, kV | 15 |
Dissipation, W: | |
anode | 350 |
grid | 20 |
Anode current (DC component), mA | 350 |
Peak anode current, A | 15 |
Maximum 1/duty factor | 500 |
Maximum pulse duration, µs | 15 |
Maximum resistance in grid circuit, kH | 10 |
Temperature, °C: | |
anode lead | 200 |
grid lead | 200 |
cathode lead | 120 |
STANDARD OPERATING CONDITIONS CW Operation | |
Heater voltage, V | 7.65-9.35 |
Anode voltage, kV | 1.5 |
Anode current, mA | 350 |
Wavelength, cm | 28 |
Output power, W: | |
in self-excited oscillator mode | 120 |
in amplifier mode | 150 |
Pulsed Operation | |
Heater voltage, V | 12.6 |
Peak anode voltage, kV | 10 |
Peak anode current, A | 12 |
Pulse duration, µs | 10 |
Peak output power, kW | 30 |
1/duty factor | 1,000 |
Wavelength, cm | 28 |
Air flow rate for envelope cooling, m³/h | 24 |