ME2T-PRO3 & ME2HT-PRO3 144/28MHz Transverter measurements

RX Measurements: ( by HG5AZB laboratory)
                              
meas equipments: R&S SMU200/A, R&S FSIQ3, Anritsu MS2661C, MS2668C

Front end : PGA-103+
IF mixer: HJK-3H+
HJK-3H+  14MHz IF measurements( pdf)
HJK-3H+  28MHz IF measurements( pdf)
Gain: 28dB max.
LO: 116MHz or 130MHz,   +23dBm

RX OIP3 > +35dBm
RX IP3  +10dBm


RX noise figure measurement ( overall)


RX OIP3/50KHz


 

RX OIP3/ 20KHz


RX OIP3/ 2KHz


OIP3= +36dBm

Min. discernible Input Signal (in case TS590S cw BW=500Hz        -146dBm

Max. spurious free Input Signal                                                 - 40.7dBm

Spurious free dynamic range                                                     105.3dB

 




 

 

 

 

 

 

 

 

 

TX Measurements

TX output signal ( Transverter unit)



 

TX Harmonics measurements

TX IM3 Measurements

TCXO PHASE NOISE

PDI +/-1ppm

AXTAL +/-0.5ppm

Short time frquency stability in case 116.000MHz AXTAL  TCXO:

03000 0 5 6.4 -5 3 #         103100 0 5 6.4 -5 3 #
103200 0 5 6.2 -5 3 #         103300 0 4 6.4 -5 3 #
103400 0 4 6.4 -5 3 #         103500 0 1 6.5 -5 3 #
103600 0 0 6.4 -5 0 #         103700 0 0 6.4 -5 1 #
103800 0 1 6.6 -5 4 #         103900 0 1 6.4 -4 2 #
104000 0 0 6.4 -5 1 #         104100 0 0 6.3 -5 1 #
104200 0 0 6.3 -4 3 #         104300 0 2 6.4 -5 3 #
104400 0 4 6.3 -4 3 #

The short time ( 15min)stability is 1Hz.